AirSpeed 5000 Server Hardware Components
10
Drive Array and Slot Locations (2-Channel Models)
For 2-channel model server data integrity, RAID 5 configuration consisting of 1 set of 5 drives is
created in the Avid AirSpeed 5000 server
n
The LSI MegaRAID Storage Manager is a RAID utility included with the Avid AirSpeed 5000
(Start > Programs > MegaRAID Storage Manager) and should be used only when instructed to
by Avid Customer Support. For more information, see the AirSpeed 5000 Administrator’s Guide.
c
The following drive configuration is created when the RAID groups are initially
configured.
Initial 2-Channel Server Setup — Data Drive Slot Locations and RAID Group
The single RAID group is configured as drives 2, 4, 5, 7, 8.
n
Slots 1, 3, 6, 9,10, 11, and 12 are empty.
Empty 4 – RAID Group 1 7 – RAID Group 2 Empty
2 – RAID Group 1 5 – RAID Group 1 8 – RAID Group 2 Empty
Empty Empty Empty Empty